    1.規格型號和安規認證
    MODEL  NUMBER  AND  SAFETY  CERTIFICATION
    • 品名規格:系列號+額定電流+額定電壓+認證符號
       Model  Number:  Part  Number+Rated Current+Rated Voltage+Approvals.
    例子[example]:
    3GFU     1A      250V                      1)系列號  Part  Number
                                                              2)額定電流  Rated  Current
    1)         2)     3)                        3)額定電壓  Rated  Voltage
    1-2 額定電流和額定電壓
    Rated Current  And  Voltage
    額定電流: 100mA~10A
    Rated Current: 100mA~10A
    額定電壓;125V/250V AC
    Rated  Voltage:125V/250V AC
    1-3標示Marking
    保險絲上需有下列標示
    The fuse shall have the following marking:
    規格:特性符號+額定電流+額定電壓
    Specification:Characteristic  Symbol+Rated Voltage
       100mA~800mA : _mA250V    1A~10A:_A250V
    Trade mark:The Manufacture’s Logo+Part Number+Approvals  
     100mA~10A:
     
    注意:對標示字樣大小沒有規定
    Note:Size of the markings have not be specified.
     
    2.適用範圍
    SCOPE
    適用於一般電子設備。Used in electronic equipment.
    3.工程圖和結構
    OUTLINE DRAWING AND STRUCTURE
    3-1 工程圖(單位:mm)
    Outline Drawing and Dimensions(Unit:mm)
     

     
    3-2結構
    Structure
    編號
    No.
    元件
    Component
    材質
    Material
    數量
    Quantity
    (1) 熔絲
    Wire
    合金
    Alloy
    1
    (2) 銅帽
    Cap
    黃銅鍍鎳
    Brass with mickel plated
    2
    (3) 本體
    Body
    玻璃管
    GLASS Tube
    1
    (4) 引線
    Lead
    鍍錫銅線
    Tinned Copper wire
    2
     
    4.外觀及形狀
    APPEARANCES AND CONFIGURATION
    4-1外觀:不應有破碎、明顯的汙斑
    Appearances:There shall no fragmentation and of remarkable blotch.
    4-2形狀:帶腳的保險絲
    Configuration:Axial Leaded Fuse.
     
    5.物理特性
    PHYSICAL CHARACTERISTIC
    5-1 拉力測試
    Tensile test
    沿端子的軸向施加10N的拉力,持續1分鐘。
    Keep pulling the cap of the fuse with 10N at axial direction for 1 min.
     
    6.電氣特性
    ELECTRICAL CHARACTERISTICS
    熔斷/電流特性:
    Pre-Arcing Time/Current Characteristic
     
    a、Breaking capacity(分断能力)(Time Lag and Fast Acting)
    50A 125V/250V AC
    b、Electrical characteristics
    Fast Acting
    Rated current % of Ampere  Opening Rating Time
     
    100mA~ 10A
    100% 200%
    4 hours, Minimum 5 Sec, Max.
    c、Temperature character
        When 100% of rating the temperature rise doesn’t exceed 75℃.
    d、ORDERING INFORMATION:
    Catalog Number Ampere Rating Voltage Rating Nominal Resistance Cold mOhms Nominal Melting i2tA2Sec. Agency Approvals
    UL CSA CQC
    3GFU-.100 .100 125/250V 4.8250 0.00194 × × ×
    3GFU-.125 .125 125/250V 3.8620 0.00289 × × ×
    3GFU-.200 .200 125/250V 1.7302 0.0114 × × ×
    3GFU-.250 .250 125/250V 1.6120 0.0225 × × ×
    3GFU-.300 .300 125/250V 0.9250 0.0295 × × ×
    3GFU-.400 .400 125/250V 0.5840 0.0695 × × ×
    3GFU-.500 .500 125/250V 0.2322 0.128 × × ×
    3GFU-.600 .600 125/250V 0.1765 0.218 × × ×
    3GFU-.750 .750 125/250V 0.1310 0.254 × × ×
    3GFU-.800 .800 125/250V 0.1215 0.304 × × ×
    3GFU-001. 1.00 125/250V 0.1056 0.508 × × ×
    3GFU-01.5 1.50 125/250V 0.0595 0.884 × × ×
    3GFU-01.6 1.60 125/250V 0.0565 0.965 × × ×
    3GFU-002. 2.00 125/250V 0.0378 2.27 × × ×
    3GFU-02.5 2.50 125/250V 0.0342 3.73 × × ×
    3GFU-3.15 3.15 125/250V 0.0253 5.95 × × ×
    3GFU-004. 4.00 125/250V 0.0174 8.86 × × ×
    3GFU-04.5 4.50 125/250V 0.0170 9.77 × × ×
    3GFU-005. 5.00 125/250V 0.0145 15.6 × × ×
    3GFU-006. 6.00 125/250V 0.0132 18.0 × × ×
    3GFU-06.3 6.30 125/250V 0.0120 19.3 × × ×
    3GFU-06.5 6.50 125/250V 0.0118 21.9 × × ×
    3GFU-007. 7.00 125/250V 0.0111 25.8 × × ×
    3GFU-008. 8.00 125/250V 0.0088 33.2 × × ×
    3GFU-010. 10.0 125/250V 0.0056 88.5 × × ×
     
     
    Average Time Current Curves


     7.環境特性
     ENVIRONMENTAL SPECIFICATION
    7-1 操作溫度範圍:-5℃~60℃
    Operating Temperature: -5℃~60℃
    7-2 保存條件
    Storage Conditions
    溫度:+10℃~60℃
    Temperature: +10℃~60℃
    在相對濕度≤75%下平均可存放3年
    On average, It can be stored below the relative humidity or 75% for 3 years.
    在非露天下,相對濕度為95%下最多可存放30天。
    Without dew, It can be kept under humidity of 95% for 30 days.
     
    8.焊接條件
    SOLDERING PAAMETERS
    8-1波峰焊
    Wave Solder
    焊接溫度:260±5℃
    Soldering Temperature:260±5℃
    焊接時間:4 Sec. Max.
    Soldering Time:4 Sec.Max.
    8-2手工焊錫
    Manual Solder
    焊接溫度:350±5℃
    Soldering Temperature: 350±5℃
    焊接時間:3 Sec. Max.
    Soldering Time: 3 Sec. Max.
     
     
    9.其他使用注意事項
    OTHER NOTICE IN USING
    如果需在保險絲上加熱縮套管,烘烤溫度與時間需參照以下規定
    If heat shrink tubing was needed,the roast temperature and time should be refer to the following.
    設定烘烤溫度:不大於150℃  烘烤時間:50s Max.
    The temperature should be sel under 150℃,roast time:50s Max.

    上一条:3.6*10mm 玻璃管慢断保险丝-----UL CSA CQC